PA-7550
Synchronized Swimming Sound System
Input Voltage to Transformer from
PA-7550 Electronics:
Isolation Transformer Test:
Technical Specifications and Test Data
Audio Isolation Impedance Matching Transformer Specifications:
Voltage: 13.6 volts +/- 0.5 volts (transformer NOT connected)
Voltage: 6.6 volts +/- 0.2 volts (transformer connected 8 Ohm tap)
Current = Voltage/Resistance = 6.6/8 = 0.83 amps
Voltage: 325 volts +/- 5 volts (DRS-8 speaker NOT connected - NO LOAD)
Current: 325/4000 = 0.08 amps
Voltage: 220 volts +/- 5 volts (DRS-8 speaker connected)
Current: 220/4000 = 0.06 amps
Hi-Pot tested at 2500 volts between transformer input leads and transformer
output leads for 5 seconds. Minimum Insulation Resistance (IR) between underwater
speaker leads (black wire or white wire) and EARTH GROUND (green wire) is
200 MegOhms. Possible current flow to earth ground is 325 volts / 200,000,000
Ohms = 0.000002 amps (2 microamps).
Ocean Engineering
Enterprises
"OCEANEARS"
Real Sound Value!
1638 Cottonwood Drive, North Canton, Ohio 44720
Phone: (330) 896-3644 ~ FAX: (330) 896-8816
E-mail: Oceaneers@aol.com

Web site design and
maintenance ~ Copyright 2001 ~ All rights reserved.